86 research outputs found

    Contrast-enhanced ultrasound identifies early extrahepatic collateral contributing to residual hepatocellular tumor viability after transarterial chemoembolization.

    Get PDF
    The mainstay of treatment for unresectable hepatocellular carcinoma is locoregional therapy including percutaneous ablation and transarterial chemo- and radioembolization. While monitoring for tumor response after transarterial chemoembolization is crucial, current imaging strategies are suboptimal. The standard of care is contrast-enhanced magnetic resonance imaging or computed tomography imaging performed at least 4 to 6 weeks after therapy. We present a case in which contrast-enhanced ultrasound identified a specific extra-hepatic collateral from the gastroduodenal artery supplying residual viable tumor and assisting with directed transarterial management

    Monitoring Progression of Ductal Carcinoma In Situ Using Photoacoustics and Contrast-Enhanced Ultrasound.

    Get PDF
    Breast cancer is the leading form of cancer in women, accounting for approximately 41,400 deaths in 2018. While a variety of risk factors have been identified, physical exercise has been linked to reducing both the risk and aggressiveness of breast cancer. Within breast cancer, ductal carcinoma in situ (DCIS) is a common finding. However, less than 25% of DCIS tumors actually progress into invasive breast cancer, resulting in overtreatment. This overtreatment is due to a lack of predictive precursors to assess aggressiveness and development of DCIS. We hypothesize that tissue oxygenation and perfusion measured by photoacoustic and contrast-enhanced ultrasound imaging, respectively, can predict DCIS aggressiveness. To test this, 20 FVB/NJ and 20 SV40Tag mice that genetically develop DCIS-like breast cancers were divided evenly into exercise and control groups and imaged over the course of 6 weeks. Tissue oxygenation was a predictive precursor to invasive breast cancer for FVB/NJ mice (P = 0.015) in the early stages of tumor development. Meanwhile, perfusion results were inconclusive (P \u3e 0.2) as a marker for disease progression. Moreover, voluntary physical exercise resulted in lower weekly tumor growth and significantly improved median survival (P = 0.014)

    Evaluation of Hepatocellular Carcinoma Transarterial Chemoembolization using Quantitative Analysis of 2D and 3D Real-time Contrast Enhanced Ultrasound.

    Get PDF
    Quantitative 2D and 3D contrast-enhanced ultrasound (CEUS) was assessed to evaluate early transarterial chemoembolization (TACE) treatment response. Seventeen patients scheduled for TACE for the treatment of hepatocellular carcinoma participated in the study. 2D and 3D CEUS were performed for each patient at three time points: Prior to TACE, 1-2 weeks post TACE, and 1 month post TACE. Peak-intensities of the tumor and surrounding liver tissue were calculated from 2D and 3D data before and after TACE and used to evaluate tumor treatment response. Residual tumor percentages were calculated from 2D and 3D CEUS acquired 1-2 weeks and 1 month post TACE and compared with results from MRI 1 month post TACE. Nine subjects had complete response while 8 had incomplete response. Peak-intensities of the tumor from 3D CEUS prior to TACE were similar between the complete and incomplete treatment groups (p = 0.70), while 1-2 weeks (p \u3c 0.01) and 1 month post treatment (p \u3c 0.01) were significantly lower in the complete treatment group than in the incomplete treatment group. For 2D CEUS, only the peak-intensity values of the tumor from 1 month post TACE were significantly different (p \u3c 0.01). The correlation coefficients between 2D and 3D residual tumor estimates 1-2 weeks post TACE and the estimates from MRI were 0.73 and 0.94, respectively, while those from 2D and 3D CEUS 1 month post TACE were 0.66 and 0.91, respectively. Quantitative analysis on 2D and 3D CEUS shows potential to differentiate patients with complete versus incomplete response to TACE as early as 1-2 weeks post treatment

    Sentinel Lymph Node Identification Using Contrast Lymphosonography: A Systematic Review

    Get PDF
    The sentinel lymph node (SLN) concept hypothesizes that metastatic cancer cells will spread through the lymphatic system to the SLN being the first one in the lymphatic chain to receive the metastatic cells, indicating that if the SLN is free of cancer cells the rest of the lymphatic chain is also without metastatic disease. Diagnostic ultrasound imaging (US) has been used to evaluate lymph nodes (LN) to determine level of suspicion and to guide LN biopsies. However, conventional US cannot be used for lymphatic mapping, which requires administration of a tracer. This has been changed with the use of contrast-enhanced US (CEUS) to detect lymphatic channels and SLNs after subcutaneous injections of microbubble-based US contrast agents (UCAs). The aim of this review is to examine the clinical evidence on the role of subcutaneous injection of UCA, known as lymphosonography, to be used as preoperative identification of SLNs in patients with breast and other cancers

    Subharmonic and Endoscopic Contrast Imaging of Pancreatic Masses: A Pilot Study.

    Get PDF
    OBJECTIVES: To use subharmonic imaging (SHI) to depict the vascularity of pancreatic masses compared to contrast-enhanced endoscopic ultrasound (EUS) and pathologic results. METHODS: Sixteen patients scheduled for biopsy of a pancreatic mass were enrolled in an Institutional Review Board-approved study. Pulse-inversion SHI (transmitting/receiving at 2.5/1.25 MHz) was performed on a LOGIQ 9 system (GE Healthcare, Milwaukee, WI) with a 4C transducer, whereas contrast harmonic EUS (transmitting/receiving at 4.7/9.4 MHz) was performed with a radial endoscope (GF-UTC180; Olympus Corporation, Tokyo, Japan) connected to a ProSound SSD α-10 scanner (Hitachi Aloka, Tokyo, Japan). Two injections of the contrast agent Definity (Lantheus Medical Imaging, North Billerica, MA) were administrated (0.3-0.4 and 0.6-0.8 mL for EUS and SHI, respectively). Contrast-to-tissue ratios (CTRs) in the mass and an adjacent vessel were calculated. Four physicians independently scored the images (benign to malignant) for diagnostic accuracy and inter-reader agreement. RESULTS: One patient dropped out before imaging, leaving 11 adenocarcinomas, 1 gastrointestinal stromal tumor with pancreatic infiltration, and 3 benign masses. Marked subharmonic signals were obtained in all patients, with intratumoral blood flow clearly visualized with SHI. Significantly greater CTRs were obtained in the masses with SHI than with EUS (mean ± SD, 1.71 ± 1.63 versus 0.63 ± 0.89; P = .016). There were no differences in the CTR in the surrounding vessels or when grouped by pathologic results (P \u3e .60). The accuracies for contrast EUS and SHI were low (\u3c53%), albeit with a greater κ value for SHI (0.34) than for EUS (0.13). CONCLUSIONS: Diagnostic accuracy of contrast EUS and transabdominal SHI for assessment of pancreatic masses was quite low in this pilot study. However, SHI had improved tumoral CTRs relative to contrast EUS

    Effect of Pulse Shaping on Subharmonic Aided Pressure Estimation In Vitro and In Vivo.

    Get PDF
    OBJECTIVES: Subharmonic imaging (SHI) is a technique that uses the nonlinear oscillations of microbubbles when exposed to ultrasound at high pressures transmitting at the fundamental frequency ie, f METHODS: Eight waveforms with different envelopes were optimized with respect to acoustic power at which the SHAPE study is most sensitive. The study was run with four input transmit cycles, first in vitro and then in vivo in three canines to select the waveform that achieved the best sensitivity for detecting changes in portal pressures using SHAPE. A Logiq 9 scanner with a 4C curvi-linear array was used to acquire 2.5 MHz radio-frequency data. Scanning was performed in dual imaging mode with B-mode imaging at 4 MHz and a SHI contrast mode transmitting at 2.5 MHz and receiving at 1.25 MHz. Sonazoid, which is a lipid stabilized gas filled bubble of perfluorobutane, was used as the contrast agent in this study. RESULTS: A linear decrease in subharmonic amplitude with increased pressure was observed for all waveforms (r from -0.77 to -0.93; P \u3c .001) in vitro. There was a significantly higher correlation of the SHAPE gradient with changing pressures for the broadband pulses as compared to the narrowband pulses in both in vitro and in vivo results. The highest correlation was achieved with a Gaussian windowed binomial filtered square wave with an r-value of -0.95. One of the three canines was eliminated for technical reasons, while the other two produced very similar results to those obtained in vitro (r from -0.72 to -0.98; P CONCLUSIONS: Using this waveform is an improvement to the existing SHAPE technique (where a square wave was used) and should make SHAPE more sensitive for noninvasively determining portal hypertension

    Ultrasound-triggered antibiotic release from PEEK clips to prevent spinal fusion infection: Initial evaluations.

    Get PDF
    Despite aggressive peri-operative antibiotic treatments, up to 10% of patients undergoing instrumented spinal surgery develop an infection. Like most implant-associated infections, spinal infections persist through colonization and biofilm formation on spinal instrumentation, which can include metal screws and rods for fixation and an intervertebral cage commonly comprised of polyether ether ketone (PEEK). We have designed a PEEK antibiotic reservoir that would clip to the metal fixation rod and that would achieve slow antibiotic release over several days, followed by a bolus release of antibiotics triggered by ultrasound (US) rupture of a reservoir membrane. We have found using human physiological fluid (synovial fluid), that higher levels (100–500 μg) of vancomycin are required to achieve a marked reduction in adherent bacteria vs. that seen in the common bacterial medium, trypticase soy broth. To achieve these levels of release, we applied a polylactic acid coating to a porous PEEK puck, which exhibited both slow and US-triggered release. This design was further refined to a one-hole or two-hole cylindrical PEEK reservoir that can clip onto a spinal rod for clinical use. Short-term release of high levels of antibiotic (340 ± 168 μg), followed by US-triggered release was measured (7420 ± 2992 μg at 48 h). These levels are sufficient to prevent adhesion of Staphylococcus aureus to implant materials. This study demonstrates the feasibility of an US-mediated antibiotic delivery device, which could be a potent weapon against spinal surgical site infection. Statement of Significance: Spinal surgical sites are prone to bacterial colonization, due to presence of instrumentation, long surgical times, and the surgical creation of a dead space (≥5 cm 3 ) that is filled with wound exudate. Accordingly, it is critical that new approaches are developed to prevent bacterial colonization of spinal implants, especially as neither bulk release systems nor controlled release systems are available for the spine. This new device uses non-invasive ultrasound (US) to trigger bulk release of supra-therapeutic doses of antibiotics from materials commonly used in existing surgical implants. Thus, our new delivery system satisfies this critical need to eradicate surviving bacteria, prevent resistance, and markedly lower spinal infection rates

    Anatomy Versus Physiology: Is Breast Lymphatic Drainage to the Internal Thoracic (Internal Mammary) Lymphatic System Clinically Relevant?

    Get PDF
    Approximately 15%−25% of breast lymphatic drainage passes through the internal thoracic (internal mammary) lymphatic system, draining the inner quadrants of the breast. This study aimed to use lymphosonography to identify sentinel lymph nodes (SLNs) in the axillary and internal thoracic lymphatic systems in patients with breast cancer. Seventy-nine patients received subcutaneous ultrasound contrast agent injections around the tumor. Lymphosonography was used to identify SLNs. In 14 of the 79 patients (17.7%), the tumor was located in the inner quadrant of the breast. Lymphosonography identified 217 SLNs in 79 patients, averaging 2.7 SLNs per patient. The 217 identified SLNs in the 79 patients were located in the axillary lymphatic system; none were located in the internal thoracic (internal mammary) lymphatic system, although it was expected in two to four patients (i.e., 4–11 SLNs). These results implied that SLNs associated with breast cancer are predominantly located in the axillary lymphatic system

    The Use of Advanced Ultrasound Techniques for the Evaluation of Uterine Fibroids pre and post Uterine Artery Embolization

    Get PDF
    Introduction: Uterine fibroids are the most common benign tumor in females of reproductive age. Uterine artery embolization (UAE) is a less-invasive alternative to hysterectomy. Our objective is to assess the ability of superb microvascular imaging (SMI) to characterize fibroid microvascularity before and after UAE compared to conventional Doppler modes using contrast-enhanced ultrasound (CEUS) and clinical outcomes as reference standards. Methods: Participants will be 40 adult females who are scheduled for UAE. Participants receive three transabdominal ultrasounds at day 0, day 14 and day 90 post-UAE using an Aplio i800 scanner. Subjects undergo examination with four non-contrast ultrasound modalities— color doppler (CDI), power doppler (PDI), color SMI (cSMI) and monochrome SMI (mSMI)— followed by CEUS. Qualitative analysis is performed by two radiologists who score the fibroids as having internal, peripheral or no vascularity. ImageJ is used to quantify fractional vascularity (FV) and signal intensity (SI). Results: Results from 31 fibroids in 22 subjects are currently available. In agreement with CEUS findings, analysis of the FV showed significant differences across modes and examination times (p\u3c0.001). Though analysis of signal intensity across imaging modes showed no significant differences (p=0.9), differences were observed across examination times (p\u3c0.001). Compared to the CEUS findings, one reader showed no difference for all modes (p=0.2), while the other reader showed no difference for CDI, PDI and cSMI (p\u3e0.1), but did show a difference for mSMI (p=0.047). Discussion: Preliminary results indicate that Doppler and SMI modes agree with CEUS findings when evaluating fibroid vascularity, and may provide clinical benefit
    • …